[1] – Park machine safely.
[2] – Allow engine to cool before servicing the cooling system.
[3] –
→NOTE:
Cooling system capacity is approximately 3.7 L (3.9 qt.).
Place a suitable container under radiator drain hose. Open radiator drain valve (A) and drain the coolant to lower thancoolant sensor level.
[4] – Disconnect wiring lead (B).
[5] – Remove sensor (C) and copper washer.
[6] – Install sensor in reverse order of removal.
a. Replace copper washer.
b. Tighten sensor to specification.
c. Refill radiator and recovery tank with approved coolant.