Depending on the type of crankcase breather system, two types of rocker lever housings are used. • Rocker Lever Cover Crankcase Breather – An internal…
Category: 6.7L Cummins
Rocker Lever Cover Mounted Crankcase Breather Install the rocker lever cover gasket. Make sure the locating tabs on the rocker lever gasket align with the…
Continuity Check NOTE: This step is only required for engines with rocker lever cover mounted crankcase breathers. NOTE: The following tests must be conducted with…
Rocker Lever Cover Mounted Crankcase Breather Do not disturb the crankcase breather gasket located on the rocker lever cover. NOTE: Exposure to oil can cause…
Rocker Lever Cover Mounted Crankcase Breather Disconnect the two wiring harness connectors from the rocker lever gasket. Use a small flat-bladed screwdriver to push in…
Depending on the type of crankcase breather system, two types of rocker lever covers are used. 1 Rocker Lever Cover Crankcase Breather – An internal…
Prior to installation, check the crossheads for damage. Refer to Procedure 002-001 in Section 2. Install the crossheads in their original location and position. Lubricate…
All rocker lever components must be installed in their original location and position. Install the adjusting screw until it stops and then install the locknut.…
Clean all parts in a strong solution of laundry detergent and hot water. Rinse parts with clean hot water. Use compressed air to dry the…
Remove the rocker lever shafts from the rocker levers. The socket at the tip of the rocker lever should not be removed. This part is…