Non-return valve A immediately stops the engine whenever the stop is activated.

Note: If the value of B is not achieved, the two rings C are not subject to enough compression to ensure the seal; any fuel loss would contaminate the lubrication oil and consequently damage the engine, F = metal gasket.

 