Home » ISX11.9 CM2250 - Service Manual » Cummins ISX11.9 CM2250 – Service Manual 001-053   Water Header Plate, Cylinder Block

Cummins ISX11.9 CM2250 – Service Manual 001-053   Water Header Plate, Cylinder Block

Preparatory Steps

TOC

 WARNING 

Do not remove the pressure cap from a hot engine. Wait until the coolant temperature is below 50°C [120°F] before removing the pressure cap. Heated coolant spray or steam can cause personal injury.
 WARNING 

Coolant is toxic. Keep away from children and pets. If not reused, dispose of in accordance with local environmental regulations.

SMALL | MEDIUM | LARGE

Remove

TOC

Remove the water header plug.

SMALL | MEDIUM | LARGE
   

Inspect for Reuse

TOC

Inspect the water header plug for cracks or other damage.

Replace if damage is found.

Inspect the o-ring for cuts, nicks, or other damage.

Replace if damage is found.

SMALL | MEDIUM | LARGE
   

Install

TOC

Lubricate the water header plug with vegetable oil.

Tighten the water header plug capscrew.

Torque Value:  47  n.m  [35 ft-lb]

SMALL | MEDIUM | LARGE
   

Finishing Steps

TOC

 WARNING 

Coolant is toxic. Keep away from children and pets. If not reused, dispose of in accordance with local environmental regulations.

SMALL | MEDIUM | LARGE
Last Modified:  11-Jun-2010