The Actuator Breakout Harness is used to measure the voltage supplied to the Injection Pressure Regulator (IPR). For electrical circuit diagnostics, install the breakout harness…
Category: International DT466
The 500 Ohm Resistor Harness is used for operational diagnostics of sensor circuits and Output State Tests for actuator control circuits.
The 12-Pin Breakout Harness is used for circuit diagnostics for the Injector Drive Module (IDM) powers and ground, actuator power and ground (EGR and VGT),…
The 4-Pin Injector Harness is used to measure continuity of the UVC wiring and injector solenoids.
The UVC Sensor Breakout Harness is used to access VREF, signal ground, and signal voltage circuits, after removing valve cover, for the following sensors: •…
The VC Gasket Breakout Harness is used to access VREF, signal ground, and signal voltage circuits, before removing valve cover, for the following sensors: •…
The 3-Banana Plug Harness is used for operational diagnostics of sensor circuits.
The Breakout Harness Kit contains the following breakout harnesses and test leads: • 3-Banana Plug Harness (ZTSE4498) • VC Gasket Breakout Harness (ZTSE4658A) • UVC…
The Breakout Box allows testing of the electronic control system components without disturbing connections or piercing wire insulation to access various signal voltages in the…
The Amp Clamp is to measure amperage draw for the glow plug and inlet air heater systems.