Install the new pass through connector. Connect the pass through connector to the injector solenoid wires. Insert
the pass through into the rocker lever housing. Tighten the capscrew.
Torque Value: 15 N•m [11 ft-lb]
Connect the actuator harness to the pass through. Install a new plastic wire tie, Part No. 3062329.