Visually inspect for damaged threads in the turbocharger mounting stud holes.
If threads are damaged (cross-threaded, etc.), chase the threads with a 3/8-16 N.C.-38 tap.
Visually inspect the manifold sections for cracks or damage.

NOTE: Install the shorter threaded end of the turbocharger mounting stud in the exhaust manifold flange.
Apply a coat of anti-seize compound to the threads.
Install the studs in the mounting flange.
Use two mounting nuts locked together to tighten the studs.
Torque Value: 40 N•m [30 ft-lb]