Home » International DT466 » International DT466 – ENGINE SYSTEMS – Fuel Management System – Main Injection (Step 2)

International DT466 – ENGINE SYSTEMS – Fuel Management System – Main Injection (Step 2)

The pulse-width controlled current to the OPEN coil is shut off, but the spool valve remains open. High
pressure oil from high pressure oil rail continues to flow past the spool valve. The intensifier piston and plunger continue to move and fuel pressure increases in the barrel. When fuel pressure rises above the VOP – about 28 MPa (4,075 psi) – the needle lifts of its seat and injection begins.