Home » KUBOTA » L2501 » KUBOTA – L2501 – HYDRAULIC SYSTEM – DISASSEMBLING AND ASSEMBLING – Disassembling Relief Valve

KUBOTA – L2501 – HYDRAULIC SYSTEM – DISASSEMBLING AND ASSEMBLING – Disassembling Relief Valve

1. Remove the plug (9), and draw out the spring (5) and the poppet (4).
2. Take out the valve seat (3).
(When reassembling)
• Take care not to damage the O-ring.

•IMPORTANT
After disassembling and assembling the relief valve, be sure to adjust the relief valve setting pressure.