Remove the protective caps from the Air Handling Clean Care Kit, Part Number 4919799, used to cover open points in the air handling system.

SMALL | MEDIUM | LARGE


Before installing the V-band clamp, coat the clamping surface with high temperature anti-seize compound.

SMALL | MEDIUM | LARGE
   


The EGR cooler connection has a male and female end. The male end of the connection goes to the exhaust manifold; the female end goes to the EGR cooler.

Install new gaskets on the pilot end of the EGR cooler connection and the EGR valve.

Install the V-band clamps loosely on the EGR cooler connection.

SMALL | MEDIUM | LARGE
   


Install the EGR cooler bellows.

Position the V-band clamps that hold the EGR cooler bellows between the EGR cooler and the exhaust manifold, as illustrated.

Rotate the exhaust manifold V-band clamp into position, as illustrated, and tighten the V-band clamps.

Torque Value:  17  n.m  [150 in-lb]