Home » ISX11.9 CM2250 - Service Manual » Cummins ISX11.9 CM2250 – Service Manual 011-024   EGR Cooler Connection

Cummins ISX11.9 CM2250 – Service Manual 011-024   EGR Cooler Connection

Table of Contents

Remove

Remove

TOC

NOTE: The EGR cooler inlet bellows can be easily damaged. Use care when loosening the V-band clamp between the EGR cooler and the inlet bellows.

Loosen the V-band clamps on each end of the EGR cooler connection.

Remove the EGR cooler connection and V-bands.

Remove and discard the gaskets.

SMALL | MEDIUM | LARGE


Use protective caps from the Air Handling Clean Care Kit, Part Number 4919799, to cover open points in the air handling system.

Remove any OEM air cleaner and charge-air cooler plumbing needed to remove the turbocharger. Refer to the OEM service manual.

SMALL | MEDIUM | LARGE