Remove
|
TOC |
NOTE: The EGR cooler inlet bellows can be easily damaged. Use care when loosening the V-band clamp between the EGR cooler and the inlet bellows.
Loosen the V-band clamps on each end of the EGR cooler connection.
Remove the EGR cooler connection and V-bands.
Remove and discard the gaskets.
|
|
|
|
Use protective caps from the Air Handling Clean Care Kit, Part Number 4919799, to cover open points in the air handling system.
Remove any OEM air cleaner and charge-air cooler plumbing needed to remove the turbocharger. Refer to the OEM service manual.
|
|
|
|
|
Last Modified: 28-Jun-2010