Install

Install

TOC

Remove the protective caps used from the Air Handling Clean Care Kit, Part Number 4919799, to cover open points on the air handling system.

SMALL | MEDIUM | LARGE


Push the o-ring over the flow assembly pilot by hand.

The o-ring must remain square during installation. Do not allow the o-ring to roll or twist.

SMALL | MEDIUM | LARGE
   


Before installing the EGR mass measurement flow assembly, coat the clamping surface of the V-bands with high temperature anti-seize compound.

If the V-band clamp was removed, loosely install the V-band clamp over the inlet side of the EGR mass measurement flow assembly.

SMALL | MEDIUM | LARGE
   


Install the EGR mass measurement flow assembly to the EGR valve by sliding the V-band in place.

Loosely install the two EGR mass measurement flow assembly mounting capscrews.

Tighten the V-band clamp.

Torque Value:  12  n.m  [106 in-lb]

Tighten the two mounting capscrews.

Torque Value:  45  n.m  [33 ft-lb]

SMALL | MEDIUM | LARGE
Last Modified:  28-Jun-2010