Install
|
TOC |
Remove the protective caps used from the Air Handling Clean Care Kit, Part Number 4919799, to cover open points on the air handling system.
|
|
|
|
Push the o-ring over the flow assembly pilot by hand.
The o-ring must remain square during installation. Do not allow the o-ring to roll or twist.
|

|
|
|
Before installing the EGR mass measurement flow assembly, coat the clamping surface of the V-bands with high temperature anti-seize compound.
If the V-band clamp was removed, loosely install the V-band clamp over the inlet side of the EGR mass measurement flow assembly.
|

|
|
|
Install the EGR mass measurement flow assembly to the EGR valve by sliding the V-band in place.
Loosely install the two EGR mass measurement flow assembly mounting capscrews.
Tighten the V-band clamp.
Torque Value: 12 n.m [106 in-lb]
Tighten the two mounting capscrews.
Torque Value: 45 n.m [33 ft-lb]
|

|
|
|
|