Home » ISX11.9 CM2250 - Service Manual » Cummins ISX11.9 CM2250 – Service Manual 011-066   EGR Mass Measurement Flow Assembly

Cummins ISX11.9 CM2250 – Service Manual 011-066   EGR Mass Measurement Flow Assembly

Table of Contents

Remove

Remove

TOC

Remove the EGR mass measurement flow assembly outlet coolant line.

SMALL | MEDIUM | LARGE


 WARNING 

The EGR mass measurement flow assembly tube can be hot. To reduce the possibility of personal injury, allow the engine to cool before removing.

Loosen the V-band clamp that connects the EGR mass measurement flow assembly to the EGR valve and slide the V-band over the inlet side of the EGR mass measurement flow assembly.

SMALL | MEDIUM | LARGE
   


Loosen the two mounting capscrews.

Remove the EGR mass measurement flow assembly.

SMALL | MEDIUM | LARGE
   


Remove the V-band clamp.

Remove and discard the o-rings from the inlet and outlet sides of the EGR mass measurement flow assembly.

SMALL | MEDIUM | LARGE
   


Use protective caps from the Air Handling Clean Care Kit, Part Number 4919799, to cover open points on the air handling system.

SMALL | MEDIUM | LARGE
Last Modified:  28-Jun-2010