Home » ISX11.9 CM2250 - Service Manual » Cummins ISX11.9 CM2250 – Service Manual 011-079   Aftertreatment Intake NOx Sensor Bracket

Cummins ISX11.9 CM2250 – Service Manual 011-079   Aftertreatment Intake NOx Sensor Bracket

Table of Contents

Install

Install

TOC

If the vibration isolators need to be replaced, apply a small amount of Lubriplate™ or vegetable oil to lubricate the rubber grommet and the lip of the metal shaft.

Insert the self contained bolt, vibration isolator, and shaft into the mounting hole in the plate.  Install the other piece of the vibration isolator onto the shaft.

NOTE: Make sure the lip of the vibration isolator is facing toward the plate.

Start part of the vibration isolator over the lip of the shaft.

Rotate the vibration isolator while pushing toward the plate.

SMALL | MEDIUM | LARGE


Make sure, when installing the vibration isolator, that it is fully installed over the lip of the shaft.

SMALL | MEDIUM | LARGE
   


Attach the plate to the bracket using the three vibration isolated mounting capscrews.

Tighten the three vibration isolated mounting capscrews.

Torque Value:  9  n.m  [80 in-lb]

SMALL | MEDIUM | LARGE
   


Attach the bracket to the engine block using the the two mounting capscrews.

Tighten the two mounting capscrews.

Torque Value:  47  n.m  [35 ft-lb]

SMALL | MEDIUM | LARGE
Last Modified:  28-Jul-2010