Home » ISX11.9 CM2250 - Service Manual » Cummins ISX11.9 CM2250 – Service Manual 017-016   Straight Thread Fittings

Cummins ISX11.9 CM2250 – Service Manual 017-016   Straight Thread Fittings

Remove

TOC

Remove the straight thread fitting.

SMALL | MEDIUM | LARGE

Clean and Inspect for Reuse

TOC

Use cleaner, Part Number 3824510 or equivalent, to clean the threads of the straight thread fittings and threaded bores.

SMALL | MEDIUM | LARGE
   


Inspect the threads of the fittings for mutilation or other damage.

Inspect the threaded bores for damage.

SMALL | MEDIUM | LARGE
   

Install

TOC

Adjustable style fittings in straight thread bosses or holes apply to all fittings (elbows, connectors, tees, check valves, etc.) that have straight threads, an o-ring, a backup washer, and a locknut.

Install a new o-ring onto the fitting.

Lubricate the o-ring.

SMALL | MEDIUM | LARGE
   


Raise the locknut, to permit the backup washer to be installed in the extreme upper end of the groove.

 
SMALL | MEDIUM | LARGE
   


Install the fitting into the straight thread boss or hole to full depth, where the metal backup washer contacts the face of the boss or hole.

SMALL | MEDIUM | LARGE
   


Position the fitting by turning it out counterclockwise up to a maximum of one turn.

Holding the pad of the fitting with a wrench, tighten the locknut and washer against the face of the boss or hole to the specified torque value. Refer to the OEM service manual for torque specifications.

SMALL | MEDIUM | LARGE
Last Modified:  20-Apr-2010