Home » ISX11.9 CM2250 - Service Manual » Cummins ISX11.9 CM2250 – Service Manual Alternator Overcharging

Cummins ISX11.9 CM2250 – Service Manual Alternator Overcharging

Symptom Tree  t014

This is symptom tree t014
Cause Correction

Battery cables or connections are loose, broken, or corroded (excessive resistance)

Check the battery cables and connections. Refer to Procedure 013-009 in Section 13
.

 

Battery cell is damaged (open circuit)

Check the condition of the batteries. Replace the batteries, if necessary. Refer to the OEM service manual.

 

Voltage regulator is malfunctioning

Check the voltage regulator. Replace the voltage regulator, if necessary. Refer to the OEM service manual.

 

Alternator is malfunctioning

Test the alternator output. Refer to Procedure 013-001 in Section 13 or the OEM service manual if the alternator is
not manufacturered by Cummins Inc.

 

Electronic fault codes active or high counts of inactive fault codes

Read the fault codes with an electronic service tool. Refer to Section TF in the Fault Code Troubleshooting Manual, Bulletin
4022225.

 
Last Modified:  19-Apr-2010