Home » John Deere » 1025R » John Deere – 1023E, 1025R and 1026R – Test HST Charge Pressure

John Deere – 1023E, 1025R and 1026R – Test HST Charge Pressure

Perform this test to check HST charge pressure. This determines if there is sufficient oil pressure to transmission.

[1] – Park machine safely.

[2] – Lock park brake.

[3] – Remove center closeout panel. See Remove and Install Center Closeout Panel in Section 90, Group 15.

[4] – Remove plug from pressure test port (A).

[5] – Install pressure gauge as follows:
– Assemble appropriate fitting, JTO3017 hose, and JTO3344 pressure gauge in test port.

[6] – Start engine and set throttle at low idle.

[7] – Check and record charge pressure.

[8] – Increase engine to high idle.

[9] – Check and record charge pressure.

[10] – Stop engine and cycle valves to relieve any pressure.

[11] – Install new O-ring on plug.

[12] – Remove gauge assembly from port. Install plug.

[13] – Install center closeout panel.

Results
– Pressure should be to specification and increase as engine speed is increased.
– If pressure is below specification, check charge pressure relief valve for debris or damage.