1. Remove the hex. head plug (1) and remove the spring (2) and relief valve assembly (3).
(When reassembling)
• When replacing the valves, check and adjust the setting pressure (see page 3-S10).
NOTE
• Take care not to damage the O-ring on the hex. head plug.


![]()