Symptom Tree t078
Cause | Correction |
---|
Battery voltage is low |
Check the batteries and the unswitched battery supply circuit. Refer to Procedure 013-009 in Section 13 and |
![]() |
Battery cables or connections are loose, broken, or corroded (excessive resistance) |
Check the battery cables and connections. Refer to |
![]() |
Engine-driven units are engaged |
Disengage engine-driven units. |
![]() |
Lubricating oil does not meet specifications for operating conditions |
Change the oil and filters. Refer to Procedure 007-013, |
![]() |
Battery capacity is below specification |
Refer to |
![]() |
Batteries are cold |
Check the battery heater. Refer to the OEM service manual. |
![]() |
Starting circuit component is malfunctioning |
Check the the starting circuit components. Refer to the OEM service manual. |
![]() |
Starting motor pinion or ring gear is damaged |
Remove the starting motor, and inspect the gear. Refer to Procedure 013-020 in Section 13, |
![]() |
Crankshaft rotation is impaired |
Check the crankshaft for ease of rotation. Refer to |
![]() |
Hydraulic lock in a cylinder |
Remove the injectors and rotate the crankshaft. Look for the source of fluid in the cylinder. Refer to Procedure 006-026 in Section 6 and |
![]() |
Internal engine damage |
Analyze the oil and inspect the filters to locate an area of probable damage. Refer to Procedure 018-003 in Section V of the Operation and Maintenance Manual, ISX11.9 CM2250, Bulletin 2883444. Remove the oil pan and inspect for a damaged camshaft, push rods, pistons and liners. Refer to Procedure 007-025 in Section 7. |
![]() |